CC-11

Bus cable 2x20AWG + 2x24AWG

Bus installation cable with increased fire resistance for backbone wiring. Electrically it is identical to the CC-01; it differs in the fire classification of its sheath and its larger outer diameter.

Key specifications

Specification
The colours of the conductors are the same as the colours of the terminals of the JABLOTRON 100+ terminal board. The cable is packed in a cardboard box as 200 m with length marks every 1 m. 1 × 2 × 20 AWG (0.5 mm2) 1 × 2 × 24 AWG (0.2 mm2) Designed for JABLOTRON 100+ alarm systems EN 60332-1-2; EN 50399; EN 61034-2; EN 60754-2 Flammability class B2CA-s1,d0,a1 Maximum operating voltage 30 V DC Made by the company ELKOND HHK a.s. for JABLOTRON

Basic description

Four cables answer the same question, each in a different way: how much current is left at the end of the run and how far the bus can reach. The higher the current, the shorter the run can be; a thicker power pair carries current further. One of the cables also has two auxiliary pairs, another has a sheath with increased fire resistance.

  • The power supply reaches even the far end of the bus, provided the run length matches the consumption of the connected peripherals.
  • The conductor colours match the terminal colours, which reduces the risk of mix-ups during wiring.
  • Handles 400 m at a total consumption of 50 mA, or only 50 m at 500 mA.
  • It has certified increased fire resistance, reaction-to-fire class B2ca.

Why choose this product

Conductors and their purpose

One pair of conductors transmits data between the control unit and the peripherals; the other is thicker and carries the power supply. It is the thicker pair that determines how far from the control unit a peripheral can be placed.

  • 4 conductors, 0.5 mm² power pair, 0.2 mm² data pair, outer diameter 6.9 mm
  • Pack of 300 m
  • Length markings every 1 m along the entire cable

Role in the system

It runs the bus from the control unit to the peripherals and can also carry components with high consumption, such as a siren.

  • Backbone wiring, fire-resistant version of the CC-01
  • Recommended for newly laid wiring
  • Run it inside the protected premises; any section outside them must be separated by a bus isolator

Conductor resistance and voltage drop

Conductor resistance increases with run length and determines the voltage drop at the far end of the bus.

  • Power pair resistance approximately 7.54 Ω per 100 m, measured over the entire loop, out and back
  • The voltage at a peripheral must not drop below 10 V; the maximum permissible drop along the cable is 2.0 V
  • Maximum operating voltage 30 V DC