JA-110Z-C
Bus terminal module
Passive non-addressable bus splitter for the JABLOTRON 100+ system. It joins the wires of two line sections in one place and holds the joint under a screw.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Maximum voltage
- 42 V AC/60 V DC
- Maximum current
- 2 A
Basic description
Passive splitters handle a place where the bus line is to end in a fixed joint that can be returned to later. Between the JA-110Z-C and JA-110Z-B, nothing decides but the board size: both versions have the same functions and the same electrical values, so the choice is determined by the free space in the box. The JA-110Z-C is the smaller of the pair, and you reach for it where the box is already largely full; where there is space left, the JA-110Z-B serves equally well. Where the joint is also to have tamper protection and system surveillance, the addressable JA-110Z is the right choice. Distribution in eight directions from one place is handled by the JA-110Z-D.
- Joins the bus wires in one place. Passive non-addressable terminal block for the JABLOTRON 100+ system.
- It is connected directly into the bus wires of the JABLOTRON 100+ system.
- The smaller board of a pair with identical functions. Functions and electrical values are the same for both versions.
Why choose this product
Passive joint on the bus
In a building, the bus line is divided according to where cables can be pulled through, not according to the diagram. Where two sections join, the installer needs a fixed point that can be relied on throughout the entire operating life. An improvised connection in the wall does not provide such certainty.
- Passive non-addressable terminal block
- Joins JABLOTRON 100+ bus wires
- The joint remains accessible for inspection
Electrical limits and choice of box
The electrical ceiling is taken into account at the line design stage, not during commissioning; once the cabling is finished, it is difficult to change. The location is then determined by the accessibility of the place and by what is already prepared in the wall. A system box and a standard flush-mounted box fit equally well, so the choice remains open.
- Maximum 42 V AC / 60 V DC
- Maximum current 2 A
- KU-68 flush box or JA-190PL installation box
Frequently asked questions
42 V AC / 60 V DC and 2 A. The value applies to the whole splitter.
In a standard KU-68 flush box as well as in the JA-190PL installation box.
No. Always connect the bus to the splitter with the system power completely switched off.
Technical specifications
- Maximum voltage
- 42 V AC/60 V DC
- Maximum current
- 2 A
Warning
- Always connect the bus with the system power completely switched off. The electrical maximum is a parameter of the whole splitter, not of an individual terminal. Do not divide it among the connected wires, otherwise you will overload the splitter.
Installation example
Always connect the bus with the system power completely switched off. The splitter is fitted in a flush box or installation box.