JA-120Z
Bus back-up booster unit for JA-100
Addressable bus booster for the JABLOTRON system: it supplies more current to peripherals and extends the wiring to places the control unit bus could not reach on its own. The input and output are galvanically separated from each other. With a back-up battery, it remains in operation even during a mains failure.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K
Check compatibilityKey specifications
- Mains power (the JA-83PWR power supply)
- 90 – 250 V AC
- Input power
- 50 VA
- Fuse
- T1.6 A/250 V, 5 x 20 mm
- Powered from the control panel BUS
- 12 V DC (9 … 15 V)
- - in standby mode
- 10 mA
- - for cable choice
- 10 mA
- Output voltage
- typically 13.7 V DC
Basic description
Where an ordinary bus splitter is not enough for the current or the wiring length, this booster takes over: it boosts the current for peripherals and extends the bus further than it would reach on its own. At the same time, it galvanically separates the output side from the input side and, with a back-up battery, keeps the connected peripherals in operation even during a mains failure.
- Boosts the current for peripherals on the bus and extends the wiring beyond the usual reach, so it also serves more distant or more heavily loaded branches of the system.
- Galvanically separates the output bus branch from the input side, verified with a test voltage of 4 kV.
- Supplies up to 2 A at the output for the connected peripherals.
- It is addressable and occupies one position in the system; in the F-Link software, it is enrolled using the LEARN button or by entering the serial number.
Why choose this product
What the booster solves
It solves long or heavily loaded bus sections where the peripherals at the end of the wiring would no longer have enough current. The range of addressed peripherals can be set to a lower or higher band as needed.
- Supports peripherals in two address ranges, 1–120 and 121–230; the 121–230 range requires a JA-107x control unit
- The tamper switches can be enabled or disabled in the settings according to the installation method
- The power supply of the output buses can be temporarily switched off in the F-Link software; after a complete power failure, it is always switched on again
Power supply and connection
It is connected to the mains and supplies the peripherals on the bus with its own galvanically separated power. It continuously diagnoses the status of the bus and the battery and reports it to the system.
- Mains power supply 110 to 230 V AC, 50 to 60 Hz, power input 50 VA, protected by a T1.6 A fuse
- Bus input 12 V DC (9 to 15 V), own consumption 10 mA; output typically 13.7 V DC with ripple up to 0.1 Vpp
- Sends diagnostics of voltage, current and battery status to the F-Link software and allows a remote firmware update
Alternative power source
With a back-up lead-acid gel battery, it keeps the connected peripherals in operation even after disconnection from the mains. The battery and the cover are ordered separately.
- 12 V lead-acid gel battery, capacity 7 to 18 Ah, with a typical service life of 4 years
- Charges the battery to 80 % of its capacity within 72 hours at the latest (for an 18 Ah battery). When the battery voltage drops to 10.9 V, it reports a low level; at 9.7 V, the whole booster switches off so that the battery is not deeply discharged
- Security grade 2 and environmental class II according to EN 50131-1 apply only when installed in the PLV-CP-L plastic housing or in the cover of another certified device with security grade 2 or higher. Operating range −10 to +40 °C, humidity up to 75 % RH, non-condensing
Frequently asked questions
No. Neither the battery nor the cover is included. The module is supplied only with the electronics and the mains power supply; order the battery separately, with a capacity of 7 to 18 Ah as required.
It provides safety isolation and solves the problem of different earth potentials of the bus power supply before and after the booster, for example between buildings or different power supply systems. The input and output sides are galvanically separated, verified with a test voltage of 4 kV.
Technical specifications
- Mains power (the JA-83PWR power supply)
- 90 – 250 V AC
- Input power
- 50 VA
- Fuse
- T1.6 A/250 V, 5 x 20 mm
- Powered from the control panel BUS
- 12 V DC (9 … 15 V)
- - in standby mode
- 10 mA
- - for cable choice
- 10 mA
- Output voltage
- typically 13.7 V DC
- Maximum ripple
- 0.1 Vpp
- Maxmum load current
- 2 A
- Galvanically separated
- (testing voltage 4 kV)
- Back-up battery 12 V
- 7 – 18 Ah
- Back-up battey type
- lead, gel
- Low battery level
- ≤ 10.9 V
- Protection againts deep discharging
- ≤ 9.7 V
- Maximum time for charging back-up battery
- < 72 h/80% C for 18 Ah
- Weight of module PCB
- 45 g
- Weight of the JA-83PWR power supply
- 360 g
- PCB dimensions
- 102 x 66 x 14 mm
- Power supply dimensions
- 170 x 80 x 65 mm
- PLV-PC-L plastic housing dimensions
- 357 x 297 x 105 mm PLV-PC-L plastic housing is not supplied!
- Classification
- security grade 2/environmental class II
- - according to
- EN 50131-1, EN 50131-6
- - environment
- general indoor
- - operational temperature range
- -10 to +40 °C
- - operational humidity
- 75 % RH, non-condensing
- - certification body
- Trezor Test s.r.o. (no. 3025)
- Also complies with
- EN 60950-1, EN 50130-4, EN 55022
Warning
- Always connect the bus with the system power supply completely switched off. A firmware update will not be completed during a power failure, either on the control unit side or on the booster side; therefore, start it only when the power supply is working. There must be no JA-11xR radio module behind a unit set to the higher address range; if you need one, set the lower range.
Installation example
Place the electronics and the mains power supply at the chosen location, for example in a separately ordered cover.
Always connect the bus with the system power supply completely switched off and the rechargeable battery disconnected.
Connect the leads to the back-up battery and observe the correct polarity: red +, black −.
Connect the mains voltage to the N and L terminals and switch the power supply on.
Enrol the module into the system in the F-Link software, using the LEARN button or by entering the serial number.
Set the range of addressed peripherals and the tamper switches according to the installation method.
Related products

HLK-PM12JBT
Switching power supply 100–240 V / 12 V/250 mA

DE06-12
Power supply 12 V/0.5 A

LT-089.07
adaptor with EU changeable plug

CC-01
Bus cable

CC-02
Bus cable

CC-03
Bus cable

CC-11
Bus cable 2x20AWG + 2x24AWG

JA-110Z
Addressable bus terminal module

JA-110Z-B
Bus terminal module

JA-110Z-C
Bus terminal module

JA-110Z-D
Multiposition bus terminal module

JA-110T
Bus short-circuit isolator module