JA-120Z

Bus back-up booster unit for JA-100

Addressable bus booster for the JABLOTRON system: it supplies more current to peripherals and extends the wiring to places the control unit bus could not reach on its own. The input and output are galvanically separated from each other. With a back-up battery, it remains in operation even during a mains failure.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K

Check compatibility

Key specifications

Mains power (the JA-83PWR power supply)
90 – 250 V AC
Input power
50 VA
Fuse
T1.6 A/250 V, 5 x 20 mm
Powered from the control panel BUS
12 V DC (9 … 15 V)
- in standby mode
10 mA
- for cable choice
10 mA
Output voltage
typically 13.7 V DC

Basic description

Where an ordinary bus splitter is not enough for the current or the wiring length, this booster takes over: it boosts the current for peripherals and extends the bus further than it would reach on its own. At the same time, it galvanically separates the output side from the input side and, with a back-up battery, keeps the connected peripherals in operation even during a mains failure.

  • Boosts the current for peripherals on the bus and extends the wiring beyond the usual reach, so it also serves more distant or more heavily loaded branches of the system.
  • Galvanically separates the output bus branch from the input side, verified with a test voltage of 4 kV.
  • Supplies up to 2 A at the output for the connected peripherals.
  • It is addressable and occupies one position in the system; in the F-Link software, it is enrolled using the LEARN button or by entering the serial number.

Why choose this product

What the booster solves

It solves long or heavily loaded bus sections where the peripherals at the end of the wiring would no longer have enough current. The range of addressed peripherals can be set to a lower or higher band as needed.

  • Supports peripherals in two address ranges, 1–120 and 121–230; the 121–230 range requires a JA-107x control unit
  • The tamper switches can be enabled or disabled in the settings according to the installation method
  • The power supply of the output buses can be temporarily switched off in the F-Link software; after a complete power failure, it is always switched on again

Power supply and connection

It is connected to the mains and supplies the peripherals on the bus with its own galvanically separated power. It continuously diagnoses the status of the bus and the battery and reports it to the system.

  • Mains power supply 110 to 230 V AC, 50 to 60 Hz, power input 50 VA, protected by a T1.6 A fuse
  • Bus input 12 V DC (9 to 15 V), own consumption 10 mA; output typically 13.7 V DC with ripple up to 0.1 Vpp
  • Sends diagnostics of voltage, current and battery status to the F-Link software and allows a remote firmware update

Alternative power source

With a back-up lead-acid gel battery, it keeps the connected peripherals in operation even after disconnection from the mains. The battery and the cover are ordered separately.

  • 12 V lead-acid gel battery, capacity 7 to 18 Ah, with a typical service life of 4 years
  • Charges the battery to 80 % of its capacity within 72 hours at the latest (for an 18 Ah battery). When the battery voltage drops to 10.9 V, it reports a low level; at 9.7 V, the whole booster switches off so that the battery is not deeply discharged
  • Security grade 2 and environmental class II according to EN 50131-1 apply only when installed in the PLV-CP-L plastic housing or in the cover of another certified device with security grade 2 or higher. Operating range −10 to +40 °C, humidity up to 75 % RH, non-condensing