JA-110Z

Addressable bus terminal module

Addressable bus splitter with front and rear tamper contacts. Once enrolled to the system, it monitors both contacts, so the branching remains under the same protection as the rest of the installation.

Compatibility

JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K

Check compatibility

Key specifications

Power
from the control panel BUS 12 V (9 … 15 V)
Current consumption (in standby mode)
5 mA
Current consumption (for cable choice)
5 mA + connected detectors
Dimensions
76 x 54 x 30 mm
Classification
according to EN 50131-1, EN 50131-3 Grade II
Operational environment according to EN 50131-1
II. Indoor general
Operational temperature range
-10 °C to + 40 °C

Basic description

The JA-110Z is an addressable bus splitter for the JABLOTRON 100+ system that joins and branches the bus. It occupies one position in the system, so take it into account when considering the control unit capacity. It pays off wherever the branching is to be under the same protection as the rest of the installation; without enrolment, it works only as a passive splitter, i.e. without tamper protection and without drop measurement. The opposite is the JA-110T isolator, which divides the bus instead, is not enrolled to the system and occupies no position.

  • Bus branching under system surveillance. The node in the box thus stops being a blind spot of the installation.
  • It is powered directly from the control panel bus and needs no power supply of its own.
  • Measures the voltage drop on the bus. Measurement runs once it is enrolled to the system.
  • Occupies one system position. Supplied in an installation box with two auxiliary terminal blocks.

Why choose this product

Addressable bus branching

In a building, the bus branches where the construction allows, not where it would suit the diagram. An addressable splitter gives such a node a permanent place and the control unit knows about it, so the branching does not remain only in the installer's head. The wires are brought to it in the order that corresponds to the actual cabling route.

  • The yellow LED flashes until it is enrolled to the system
  • Two auxiliary terminal blocks with four parallel terminals each
  • No bus terminal is permanently designated as an input or output

Power supply and connection

The splitter makes do with what it has available on the bus. You enrol it to the system in F-Link by pressing the front tamper contact or by entering the serial number. You choose the position yourself, so the module can sit in the overview where it logically belongs.

  • Nominal voltage 12 V DC, range 9 to 15 V
  • Standby consumption 5 mA; for cable selection, the connected detectors are added
  • Dimensions 76 × 54 × 30 mm, Security Grade 2, environmental class II

Tamper protection and signalling

The splitter shows its status by visual signalling. The yellow LED flashes until the module is enrolled to the system and lights steadily in the event of a fault. The red LED flashes at every change in the state of the tamper contacts.

  • Once enrolled, it monitors the front and rear tamper contacts
  • The rear contact can be disabled in the module settings; it is enabled by default
  • Once enrolled, it measures the voltage drop on the bus