JA-110Z-D
Multiposition bus terminal module
Passive non-addressable bus splitter for the JABLOTRON 100+ system for larger installations. From one place, it distributes the line in up to eight directions.
Compatibility
JA-100K, JA-101K, JA-106K, JA-103K, JA-107K, JA-108K, JA-102K
Check compatibilityKey specifications
- Maximum voltage
- 42 V AC/60 V DC
- Maximum current
- 2 A
Basic description
In a larger installation, a whole bundle of cables runs from the control unit into the building, and they all have to start somewhere. Compared with the JA-110Z-B and JA-110Z-C pair, the JA-110Z-D distributes the bus in up to eight directions and can also be divided into two separate units, so one part of the building can hang on a different line section from the other. Where it is enough to join two cable sections at one point, the JA-110Z-B or JA-110Z-C is the simpler choice. Where the joint is also to have tamper protection and system surveillance, the addressable JA-110Z is the right choice. This splitter offers the most mounting options of the whole trio, from a separate box to fitting directly in the control unit.
- Cables from the whole building meet on one board. Passive non-addressable terminal block for the JABLOTRON 100+ system.
- It is connected directly into the bus wires. It needs no configuration or enrolment to the system.
- Distributes the bus in up to eight directions. One location can thus serve even a large installation.
Why choose this product
A bundle of lines at one point
In a larger installation, not one cable but a bundle of lines runs from the control unit to different parts of the building. The splitter gives them a common point that can be returned to at any time and where you can see where each cable continues. This eliminates improvisation in the box and tracing where the bus branched in the building.
- Passive non-addressable terminal block
- For larger JABLOTRON 100+ installations
- The joint remains accessible for inspection
Two branches from one splitter
Sometimes one part of the building is to belong to a different bus section from the other, and running another cable from the control unit for this is not worthwhile. The splitter handles this itself, directly on the board and without any additional material. The design engineer can thus plan the division in advance, and the installer simply carries it out in the box.
- Opening the jumpers creates two independent branches
- Electrical maximum 42 V AC / 60 V DC and 2 A
- The division is visible on the board with the naked eye
Where the splitter is fitted
Where the splitter goes is usually decided by where the cables end and how much space is left in the distribution board. At the control unit, it serves as the central bus distribution point; closer to the target locations, it shortens the lines, but the installer then has the joint further from the other equipment. Whichever you choose, expect to return to the splitter when extending the installation.
- Mounting in a JA-194PL box
- PLV-CP-M and PLV-CP-L covers
- Direct installation in the JA-106K control unit
Frequently asked questions
No. Always connect the bus to the splitter with the system power completely switched off.
In a JA-194PL box, in PLV-CP-M and PLV-CP-L covers or directly in the JA-106K control unit.
In the number of directions and the option of dividing it into two independent branches. The JA-110Z-B and JA-110Z-C are simple terminal blocks for joining wires in one place.
Technical specifications
- Maximum voltage
- 42 V AC/60 V DC
- Maximum current
- 2 A
Warning
- Always connect the bus with the system power completely switched off. The electrical maximum is a parameter of the whole splitter. Do not divide it among the individual branches, not even after splitting with the jumpers, otherwise you will overload the splitter.
- The splitter is fitted directly in the control unit only where a place is prepared for it; elsewhere, use a box or a cover.
Installation example
Always connect the bus with the system power completely switched off. The splitter is fitted in a box, in a cover or directly in the control unit.